- LCD Status display
- LED Status display
- Operating buttons
- Motor connection (Two optional connectors are available for the 600 VA and 3.5 kVA version)
- 9 digital inputs
4 digital outputs
1 digital encoder output
2 analog ± 10 V inputs
1 analog + 10 V output
- USB connector
- Mains connector (On/off switch on the front panel of the 600 kVA and 3.5 kVA version)
The oscilloscope function allows optimization of the axes in the machine via the drive-setup-tool without additional measuring equipment.
The clear design of the software allows intuitive parameterization via graphics and block diagrams. The „Parameter-Wizard“ guides the user step-by-step through the system configuration and allows intuitive setup of the device via help messages and comments.
Technichal Specifications of SD2T
1-Phase Supply
115 – 230 V Mains supply (AC) / 60 V output voltage
| 300 VA |
Ir: 8 A |
Ip: 14 A |
120 x 240 x 220 mm |
| 600 VA |
Ir: 14 A |
Ip: 28 A
|
120 x 275 x 220 mm |
115 – 230 V Mains supply (AC) / 220 V output voltage
| 3.5 kVA |
Ir: 10 A |
Ip: 28 A |
120 x 275 x 220 mm |
Ir = rated current, Ip = peak current (1s).
Stated currents are rms values.
Voltage limits: -10% / +10%
The device dimensions are defined as height x width x depth, related to the mounting dimensions.
Errors and omissions excepted.