SD2T

The All-in-one Solution for High-speed Applications

The Interfaces of SD2T

SD2T Niedervolt Schnittstellen
  1. LCD Status display
  2. LED Status display
  3. Operating buttons
  4. Motor connection (Two optional connectors are available for the 600 VA and 3.5 kVA version)
  5. 9 digital inputs
    4 digital outputs
    1 digital encoder output
    2 analog ± 10 V inputs
    1 analog + 10 V output
  6. USB connector
  7. Mains connector (On/off switch on the front panel of the 600 kVA and 3.5 kVA version)

Software for Initial Operation and Parameterization:
drivemaster2

The oscilloscope function allows optimization of the axes in the machine via the drive-setup-tool without additional measuring equipment.


The clear design of the software allows intuitive parameterization via graphics and block diagrams. The „Parameter-Wizard“ guides the user step-by-step through the system configuration and allows intuitive setup of the device via help messages and comments.


Technichal Specifications of SD2T

1-Phase Supply

115 – 230 V Mains supply (AC) / 60 V output voltage
300 VA Ir: 8 A Ip: 14 A 120 x 240 x 220 mm
600 VA Ir: 14 A Ip: 28 A
120 x 275 x 220 mm
115 – 230 V Mains supply (AC) / 220 V output voltage
3.5 kVA Ir: 10 A Ip: 28 A 120 x 275 x 220 mm

 

Ir = rated current, Ip = peak current (1s).
Stated currents are rms values.
Voltage limits: -10% / +10%
The device dimensions are defined as height x width x depth, related to the mounting dimensions.