FC72

The Main Spindle Drive for Machine Tools

The Interfaces of FC72

FC72C Schnittstellen
  1. Profibus
  2. Parameterization and diagnosis
  3. 8 digital inputs and 8 digital outputs
  4. Special functions
  5. Analog values (i.e. reference speed values)
  6. Motor encoder
  7. Motor encoder signals for control
  8. Safety contact
  9. 24 V supply
  10. Mains supply
  11. Motor connection

Software for Initial Operation and Parameterization:
vector7x

The software vector7x is used for parameterizing the frequency converters and for optimizing the application. Various tools allow easy optimization of the controller.

The graph-supported parameterization of the position controller allows optimizing the tool change or the behavior in threading operations.


The parameterization of the speed controller can be optimized while the motor is running


Technical Specifications of FC72

Compact device devices with integrted power supply and air cooling

3 x 480 V Mains supply (AC)
8 kVA Ir: 12 A Ip: 18 A 390 x 170 x 235 mm
13 kVA Ir: 19 A Ip: 29 A 390 x 170 x 235 mm
20 kVA Ir: 29 A Ip: 50 A 460 x 220 x 235 mm
30 kVA Ir: 44 A Ip 60 A 460 x 220 x 235 mm

with air cooling

Supply via external power supply PS10
40 kVA Ir: 58 A Ip: 100 A 480 x 350 x 260 mm
55 kVA Ir: 80 A Ip: 120 A 480 x 350 x 260 mm
70 kVA Ir: 101 A Ip: 140 A 480 x 350 x 260 mm

with water cooling

Supply via external power supply PS10
100 kVA Ir: 145 A Ip: 200 A 480 x 350 x 260 mm
125 kVA Ir: 181 A Ip: 230 A 480 x 350 x 260 mm
150 kVA Ir: 217 A Ip: 245 A 480 x 350 x 260 mm
170 kVA Ir: 250 A Ip: 250 A 480 x 350 x 260 mm

Ir = rated current, Ip = peak current.
Stated currents are rms values.
The device dimensions are defined as height x width x depth, related to the mounting dimensions.
FC71 for 200 V supply voltage: For applications with 200 V mains supply devices with equivalent output currents are provided on request. The low voltage of 200 V results in a reduction of the output power.

Technical Specifications Power Supply PS10

The Power Supply PS10 with air cooling supplies FC72 with energy. Alternatively, an existing power supply in the machine can be used for supplying the frequency converters.

3 x 480 V Mains supply (AC)
26 kW
30 kVa 480 x 150 x 260 mm
48 kW 55 kVa 480 x 150 x 260 mm
86 kW 100 kVa 480 x 300 x 260 mm
120 kW 150 kVa 480 x 300 x 260 mm

Voltage limits at 480 V: 400 V -10% bis 480 V +10%
The device dimensions are defined as height x width x depth, related to the mounting dimensions.
Subject to changes and errors.

Errors and omissions excepted.