aeocon for Hydro­electric Power Plants

The Smart All-rounder

The Interfaces of aeocon

Aeocon5000 Schnittstellen2
  1. Grafic-Display for current performance, energy, status etc.
  2. 3 LEDs for status display
  3. Operating buttons for menu control
  4. Separated connection area
  5. Generator
  6. Ballast resistor
  7. RS232 / RS485
  8. COM & Handshake
  9. Grid / mains

Control Panel

aeocon comes with a data logger including a real-time clock which continuously records the performance of the power plant. The memory is equipped with a battery ensuring that no data will be lost during downtimes of the system. The graphic display of the converter provides all relevant information on the operating state of the system. The following values can be displayed:

  • Mains power (PMains)
  • Mains energy (EMains)
  • Performance of the heating resistance (PHeat)
  • Energy of the heating resistance (EHeat)
  • Speed of the wind turbine (nWT)
  • Generator voltage (UW)
  • Converter temperature (Taeocon)
  • Mains voltage (UMains)
  • Mains current (IMain)
  • Mains frequency (fMains)

The languages English, German and French can be selected via the terminal.


Technical Specifications of aeocon

Input (3-Phase)
Generator type Permanently excited synchronous generator
Operating voltage range 40 VAC to 340 VAC
Maximum voltage 400 VAC
Optimum generator voltage at rated power 300 VAC
Ballast circuit
Switching threshold 480 VDC / 340 VAC Generator voltage
External ballast resistor 10 - 46 Ohms, 5 KW
Output(1-phase)
Rated voltage 230 VAC
Rated power aeocon 4000/ 5000 4 KW / 5 KW
Rated current aeocon 4000/ 5000 17 A / 22 A
Mains frequency 50 HZ / 60 HZ
Mains monitoring DIN V VDE V 0126-1-1
EN 50438
EN 50438 Ireland
EN 50438 France
EN 50438 Netherlands
EN 50438 Portugal
EN 50438 Spain
G83/1-1
Other are currently prepared
General data
Weight 26.6 kg
Dimensions (h x w x d) 572 x 306 x 213 mm
IP code IP54
Type of cooling Natural convection
Admissible ambient temperature -20 °C to +40°C

The stated current and voltage values are rms values.

Errors and omissions excepted.