- Safety Intergrated: Restart lock to achieve category 4 according to EN 13849-1:2008-12, EN 62061:2008-04 and
EN 61508:2002-11; Safety level SIL 3
- USB connector: Parameterization, diagnosis and operation
- RS232 / CAN interface
- 2 Analog reference value interfaces: +/-10 V; 2 analoge outputs: 0-10 V
- Universal motor encoder interface:
Hall sensor, linear Hall sensor, magnetoresistive sensor, namur sensor (pulse generator), SinCos encoder
- 9 digital inputs and 5 digital outputs
- Optical fiber Profibus adapter, connection via SERVOLINK 4
- Mains supply
- Motor cponnection
Operation Unit (optional)
LCD status display for the indication of operating data:
- Parameters
- Reference / actual speed
- Load display
- Active spindle
- Error messages
LED status displays for:
- Ready for operation
- Load message
Software for Initial Operation and Parameterization: drivemaster2
The oscilloscope function allows optimization of the axes in the machine via the drive-setup-tool without additional measuring equipment.
The clear design of the software allows intuitive parameterization via graphics and block diagrams. The „Parameter-Wizard“ guides the user step-by-step through the system configuration and allows intuitive setup of the device via help messages and comments.
Technical Specifications of SD2S
1-phase Supply
50 V Mains supply (AC)
| 0.3 kVA |
Ir: 10 A |
Ip: 14 A |
250 x 75 x 180 mm |
| 0.7 kVA |
Ir: 20 A |
Ip: 28 A |
250 x 110 x 180 mm |
230 V Einspeisung (AC)
| 1.4 kVA |
Ir: 10 A |
Ip: 14 A (28 A)* |
250 x 75 x 180 mm |
| 3.8 kVA |
Ir: 20 A |
Ip: 28 A (56 A)* |
250 x 110 x 180 mm |
3-phase Supply
50 V Mains supply (AC)
| 1.5 kVA |
Ir: 20 A |
Ip: 28 A |
250 x 110 x 180 mm |
230 V Mains supply (AC)
| 6.9 kVA |
Ir: 20 A |
Ip: 28 A (56 A)* |
250 x 110 x 180 mm |
480 V Mains supply (AC)
| 9.7 kVA |
Ir: 14 A |
Ip: 28 A (56 A)* |
250 x 110 x 180 mm |
| 15 kVA |
Ir: 23 A |
Ip: 29 A |
390 x 180 x 180 mm |
| 20 kVA |
Ir: 35 A |
Ip: 56 A |
460 x 225 x 200 mm |
| 30 kVA |
Ir: 44 A |
Ip: 70 A |
460 x 225 x 200 mm |
| 55 kVA ** |
Ir: 80 A |
Ip: 113 A |
460 x 250 x 200 mm*** |
Ir = rated current, Ip = peak current.
Stated currents are rms values.
Voltage limits at 50 V: 50 V -10% up to 64 V +10%
Voltage limits at 230 V: 110 V -10% up to 230 V +10%
Voltage limits at 480 V: 230 V -10% up to 480 V +10%
The device dimensions are defined as height x width x depth, related to the mounting dimensions.
* Version with higher peak current.
** Water cooling also available.
*** Premliminary data.
DC-Mains Supply
680 V (DC) Mains supply - supply via external power supply
| 55 kVA |
Ir: 80 A |
Ip: 113 A |
480 x 355 x 260 mm |
Technical Specification Power Supply PS10
3 x 480 V Mains supply (AC)
| 48 kW |
55 kVA |
480 x 150 x 260 mm |
Voltage limits at 480 V: 400 V -10% up to 480 V +10%
The device dimensions are defined as height x width x depth related to the mounting dimensions.
Errors and omissions excepted.